ITYS ES

Solution for electrical substations
Single/single phase UPS from 1000 to 3000 VA - Electrical Substation

The solution for

• Control devices
• Electric lines

Advantages

High protection and high availability

• The ITYS ES series is a range of compact UPS systems available in 1000, 2000 and 3000 VA models with on-line double conversion technology (VFI) with sinusoidal absorption.
• ITYS ES guarantees permanent regulation of the output voltage and frequency. This technology is compatible with all IT and industrial applications and operating environments, installations with generator sets included.
• Wide tolerance on input voltage ensures that switchovers to battery mode are infrequent, significantly prolonging battery lifetime.
• The automatic bypass device switches over in zero time in the event of overload or failure, guaranteeing uninterrupted services.

Straightforward to install and easy to use

• The UPS is shipped ready for connection with internal batteries connected and charged.
• ITYS ES, with the manual bypass option is easy to install without any special plant engineering  preparation, as it is equipped with built-in thermal protection.
• The LCD monitoring/control panel and a buzzer make the equipment extremely easy and intuitive to use. The graphic indicating the power distribution path shows at a glance whether or not the system is working as it should.
• Battery efficiency can be tested via the control panel or using dedicated software.

Operating efficiency and versatility

• The versatility of these models makes them suitable for protecting critical devices in the industrial field.
• The standard equipment and communication accessories have been specially designed to satisfy the typical needs of installation or use in transformer cabins (i.e. tropicalized boards).
• In situations where automatic power management procedures are required, the communication software can be used to programme scheduled start-up and shutdown times.
• Restarting the UPS from the battery to power the DG before closing the main isolator.

  • Standard and option features

  • Technical Data

     

    Manual bypass (option)

     

    Specially designed for ITYS ES, the manual bypass option enables:
    • simplified installation: connection to the system is made with industrial grade terminals, while connection to the UPS is via the pre-wired plug and socket supplied.
    • easy maintenance and uninterrupted operation: thanks to the manual bypass isolator it is possible to service or replace the UPS while maintaining the power supply to the devices downstream in complete safety for the operator. This operation has been specially devised to be simple to carry out, even in an emergency.
    • increased level of equipment immunity to surge voltages, typical for this type of application, thanks to suitable surge arrestors included in addition to standard UPS protection.
      itys_025_a_101x120.jpg

     

    Programmable clean contacts board (option)

     

    Dedicated interface with clean contacts, can be installed on the rear slot: gives the status of the UPS with five potential-free contacts and provides an input for remote emergency stopping (EPO).

    itys_023_a_108x80.jpg

      itys_024_a_gb_370x223.png

     

    Rear view connections

    itys_es_raccordements.png

    1. Fan
    2. Slot for optional communication boards
    3. RS232 serial port (JBUS protocol)
    4. Telephone / modem / ASDL line protection
    5. Output sockets (IEC 320)
    6. Input socket (IEC 320)
    7. Manual bypass
    8. Input protection (Thermal breaker)
    9. Output terminals
    10. Connection for external battery cabinet (LB models only)

     

     

    Technical data

     

      ITYS ES - UPS
    Sn 1000 VA 2000 VA 3000 VA
    Pn 800 W 1600 W 2400 W
    Input / output 1/1
    Input
    Rated voltage 230 V (110÷300 V)
    Rated frequency 50/60 Hz
    Power factor 0.98
    Output
    Rated voltage 208 / 220 / 230 / 240 V (± 2 %)
    Rated frequency 50 / 60 Hz (45÷55 Hz / 54÷66 Hz)
    Overload up to 150 % for 10 seconds
    Crest factor 3:1
    Connections 3 x IEC 320
    (C13)
    6 x IEC 320
    (C13)
    4 x IEC 320
    (C13) + terminals
    Batteries
    Type sealed lead-acid maintenance free - expected lifetime 3-5 years
    Back-up time at 75% of the rated load(1) 10 min 17 min 9 min
    Sized for a back-up time of 115 min @ 50 W 154 min @ 100 W 216 min @ 150 W
    Back-up time(2) + switching back on 60 min @ 50 W 60 min @ 100 W 60 min @ 150 W
    Battery test
    Communication
    Interfaces RS232 - USB
    Ethernet adapter NET VISION (TCP / IP & SNMP) optional card
    Local communication software Local View
    Efficiency
    Online mode up to 92%
    Environment
    Ambient service temperature 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime)
    Relative humidity < 95% non-condensing
    Maximum altitude 1000 m without de-rating
    Noise level at 1 m < 50 dBA
    UPS cabinet
    Dimensions W x D x H 145 x 400 x 220 mm 192 x 460 x 350 mm
    Weight 13 kg 31 kg 60 kg
    Degree of protection IP20
    Standards
    Safety IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
    EMC IEC/EN 62040-2, AS 62040.2
    Product certification CE, RCM (E2376)

      ITYS ES - Manual bypass(3)
    Sn 1000 VA 2000 VA 3000 VA
    Input
    Type of terminals CBD6
    Wire size 6 mm2 max
    Bypass
    Switching positions 1: UPS - 2: MAINS
    Switching time 6 ms max
    Load output
    Type of terminals CBD6
    Wire size 6 mm2 max
    UPS supply output
    Type of socket IEC 320 10 A IEC 320 16 A
    Surge arrestors (on request)
    Type “L” in compliance with CEI EN 61643-11
    L/N pulse current 40 kA (8/20) max
    VAC N/GND 255 V max
    VAC L/N 320 V max

    (1) @ 25 °C with charged battery.
    (2) Factory setting: back-up time limited to 60 minutes to permit subsequent restarting with battery.  
    (3) Upon request.