mod_029_b_pro_jpg

MODULYS RM

UPS protection for 19” rack integration
Single/single phase UPS from 1.5 to 9 kVA

The solution for

• e.business
• Server farms
• Telecommunications
• Medical
• Computer networks

Advantages

A 19” rack solution

• The Mod-RM series enables the UPS and all the protected equipment (HUB, server, back-up units, etc.) to be integrated into a single 19” rack. These modules are prewired so that connection is easier, simplifying installation.

An adaptable system

• Mod-RM has been specifically designed for usage up to 9 kVA, which requires a combination of reliability and adaptability.
• The free slots in each model enable the Mod-Power to be added to provide redundancy for the system or to increase the power.

Modular back-up time

• In the same way, the spaces available enable the Mod-Battery to be added to increase back-up time.

System upgrades

• Units bought separately (Mod-TW or Mod-RK) can be installed at a later date in a Mod-System, fulfilling your needs for modularity and redundancy.

  • Standard and option features

  • Technical Data

     

    Basic configurations

     

    Expandable from 1.5 kVA to 9 kVA


    Model Mod-RM 315
    Mod-Power 1 x 1500 VA
    Battery pack 1
     

    Model Mod-RM 330
    Mod-Power 1 x 3000 VA
    Battery pack 2

     

     

    UPS and internal batteries

     

     

     


    Technical data

     

    Sn [VA] 1500 3000
    Pn [W] 1050 2100
    Input / output 1/1  
    Input
    Rated voltage 230 V
    Voltage tolerances ± 20% (up to -30% at 70% nominal load)
    Rated frequency 50/60 Hz
    Frequency tolerance ± 10%
    Power factor > 0.99
    Output
    Rated voltage 230 V
    Voltage tolerance ± 3% (adjustable 208/220/240 V)
    Rated frequency 50/60 Hz
    Frequency tolerance ± 2% (± 0.1% autonomous frequency)
    Overload 110% for 1 minute, 130% for 10 seconds, 200% for 5 cycles
    Crest factor 3/1
    Bypass
    Rated voltage voltage selected
    Voltage tolerance ± 15%
    Rated frequency frequency selected
    Frequency tolerance ± 2%
    Efficiency
    Online mode @ 100 % of load up to 91%
    Eco Mode 97%
    Environment
    Operating environment temperature from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life)
    Relative humidity 0% - 90% without condensation
    Maximum altitude 1000 m without derating (max. 3000 m)
    Mod-System
    Dimensions W x D x H 3 slots 19" x 564 mm x 13U
    Weight with standard batteries 57 kg (Mod-RM 315), 68 kg (Mod-RM 330)
    Degree of protection IP20
    Acoustic level at 1 m (ISO 3746) < 52 dBA
    Heat dissipation 780 W
    Input connections terminals
    Output connections terminals + 2 x IEC 320 C19 (16 A)
    Standards
    Safety IEC/EN 62040-1
    EMC IEC/EN 62040-2
    Performance IEC/EN 62040-3
    Product declaration CE