RESYS B 470 / B 471 / B 475

• Class AC, class A and class B residual current monitoring
• Tripping threshold with time delay
• Pre-alarm with LED and relay
• Modular case

 
 

RESYS M40

• TRMS measurement principle
• Class AC and class A residual current monitoring
• Fixed tripping threshold and time delay
• 2.5 module case

 
 
 

RESYS P40

• TRMS measurement principle
• Class AC and class A residual current monitoring
• Adjustable tripping threshold and time delay
• LED bar graph
• Configurable pre-alarm
• Flush-mounted casing 48x48x90mm

 
 
 

RESYS M20

• TRMS measurement principle
• Class AC and class A residual current monitoring
• Fixed tripping threshold and time delay
• 2.5 module case

 
 
 

DLRD 460-12

• Simultaneous monitoring of 12 branches
• Measurement of AC, pulsed DC and pure DC currents (type AC, A and B)
• TRMS measurement
•  Adjustable time delay PConnection of split core or closed toroids
•  Working mode of relays adjustable
• Automatic or manual reset
• Adjustable sensitivity
•  Permanently monitoring of toroid connection
•  RS485 communication

 
 
DLRD 490-12  

DLRD 490-12

• Simultaneous monitoring of 12 branches
• Measurement of AC, pulsed DC and pure DC currents (type AC, A and B)
• Measurement of pure DC current with specific W-B (type B) series torus
• TRMS measurement
• Adjustable time-delay
• Adjustable time delay PConnection of split core or closed toroids
• Compatible with other torus ranges (contact us)
• Working mode of relays adjustable
• Automatic or manual reset

• Bargraph display or LCD
• Adjustable sensitivity
• Permanently monitoring of toroid connection
• RS485 communication

 
 
 

Core balance transformers

• Circular or rectangular closed toroids
• Opening toroid
• Special toroids for RESYS class B

 
 

Surge Protective Devices

 

SURGYS G50-PV

• PHOTOVOLTAIC applications
• 500, 600, 800, 1000 VDC

• Imax = 40 kA

• Up = 1.8 kV à 3.6 kV

• Monobloc design
• Plug-in protection modules

• Status display and signaling contact
 

 
 

SURGYS G140-F

• Surge Protective Device Type 1

• Imax = 140 kA

• Up = 2.5 kV

• Status display and signaling contact

 
 
 

SURGYS G40-FE

• Surge Protective Device Type 1 and 2

• Imax = 40 kA

• Up = 1.5 kV

• Status display

• Signaling contact

 
 
 

SURGYS G70

• Surge Protective Device Type 2

• Imax = 70 kA

• Up = 1.8 kV

• Monobloc design
• Plug-in protection modules

• Status display and signaling contact

 
 
 

SURGYS D40

• Surge Protective Device Type 2

• Imax = 40 kA

• Up = 1.8 / 1.5 kV
• Monobloc design

• Plug-in protection modules

• Status display and signaling contact

 
 
 

SURGYS E10

• Surge Protective Device Type 2 and Type 3

• Imax = 10 kA

• Up = 1.3 /1.5 kV
• Monobloc design

• Plug-in protection modules

• Status display and contact

 
 
 

SURGYS Low voltage

• RS-2 : RS422 or RS 485, T2 Digital phone lines and Ethernet links

• mA-2 : Measuring loops, 4-20mA signals and fieldbuses

• TEL-2 : Analog phone network

• COAX : Telecom network

 
 
 

SURGYS L1

• Coordination inductance